11
1 - fAiLURES
1.1 - fAiLURE READiNG
1.
f
a I l u r e s
1.1
re a d I n g t h e f a I l u r e s
When the “Failure” function is displayed, press the conrm button
to display the present failures.
If no failures are currently present, after pressing the conrm button
the message “End failures” will be displayed.


1.2
r
e s e t t I n g t h e f a I l u r e s
By conrming this function all current failures will be reset.
1.2 – fAiLURE RESET
1.3 - MOTOR ERRORS
1.3
mo t o r e r r o r s
With this function the failed motors are displayed for approximately
1 second. In the event the is more than 1 motor errors at the same
time, scrolling between errors is automatic.
1.4 - MOTORS’ STATUS
1.4
mo t o r s s t a t u s
This function is used to read the last failure that occurred in each
spiral, even if the machine conguration has an empty position.
A motor can be in one of the following conditions:
- motor functioning
- motor not present; when the motor is not detected at machine
power-on
- motor disconnected; when a motor detected at machine start-up is
not detected during a selection
- motor blocked; when the positioning button is not operated within
the “timeout”
- empty spiral; when, with the dispensing control (photocells) in-
stalled, no dispensed product is detected.


1.5 - RESET MOTOR ERR.
1.5
re s e t m o t o r e r r o r s
By conrming this function all current failures regarding the motors
will be reset.