P2125EN00
01 - 2008

30
4 - TEST
4.1 - TEST SELECTiON
4.2 - MOTOR TEST
4.3 - AUTOTEST
4.
te s t
4.1
te s t s e l e c t I o n
With this function it is possible to simulate the normal dispensing of
products without inserting any money.
It is therefore possible to check the functioning of the motor rotation
by pressing the selection buttons.
4.2
m
o t o r t e s t
This function is used for actuating all motors in a sequence to check
their correct functioning.
4.3
a
u t o t e s t
This function allows testing, in a semiautomatic way, of the main ma-
chine components. When pressing the conrm button, the message
AUTOTEST” will be start blinking.
It is possible to cancel each operation and go to the next one by
pressing the exit button, but conrming with the conrm button to
start the autotest routine. Some checks occur automatically, others
need the manual operation of the monitored component.
In a sequence:
- Push-button panel test; the machine will display the number of the
button which must be pressed and awaits the actuation before going
to the next button.
- Temperature test; the machine will display the value of temperature
detected by the probe. In the event of interruption the value -11.0 is
displayed; in the event of short-circuit the value 41.0 is displayed.
- Buzzer test; the machine will emit a series of test sounds.
- Compressor test; the compressor is activated/deactivated using
the
and “
buttons.
- Selection test; the machine will simulate the dispensing of each
selection in a sequence.
- Coin mechanism test; the machine checks that communication
with the coin mechanism takes place correctly and which validator
lines are set as being active.
- Photocell test; in the event where the machine is equipped with a
device for detecting the passage of products the light beam reading
and interruption are checked.
- Dispensing compartment lock test; in the event where the machine
is equipped with a device for locking the dispensing compartment,
the
and “
buttons are used for locking and unlocking the
compartment opening.
- Direct push-button test; the machine will display the number of the
button which must be pressed and awaits the actuation before going
to the next button.