The machine is locked if the compressor runs non-stop for more than 24 hours.
c
o I n m e c h a n I s m
The machine is locked if it receives a pulse longer than 2 seconds on a validator line or the communication
with the serial coin mechanism does not take place for more than 30 seconds (Executive protocol) or 75 sec-
onds (BDV protocol).
ram d
a t a
One or more areas of the RAM contain wrong data which was corrected with the default values.
The machine will continue to function, but it would be advisable to initialise as soon as possible.
P
r o b e
The machine is locked after 5 minutes if the internal temperature sensor is disconnected; the display will indi-
cate a temperature of -11° C.
The machine is locked after one hour if a sensor short circuit is detected; in this case the display will indicate a
temperature of +41° C.
m
o t o r e r r o r s
With this function the failed motors are displayed for approximately 1 second.
Scrolling through all failed motors is automatic.

d
I s P e n s I n g c o m P a r t m e n t l o c k
When the function “unlock compartment with dispensing” and the parameter “out of service if open” are active,
the machine will lock if the locking device of the dispensing compartment remains blocked when closed or it
does not close within the programmed time.