P2125EN00
01 - 2008

19
2.2.2.1 - SETTLiNG TiME
2.2.2.2 - MONEY RETURN
2.2.2.3 - EMPTY SEL.CONTR.
2.2.3 - COMP.LOCK PARAM.
2.2.3.1 - OPERATiNG MODE
2.2.3.2 - UNLOCK TiME
2.2.2.1
se t t l I n g t I m e
The vending machine can be tted (as standard feature or as
optional according to the model) with a device that, by means of
photocells, detects the passage of dispensed products.
With this function it is possible to set for each spiral/selection a rota-
tion time further to the normal rotation to allow correct dispensing of
the product.
2.2.2.2
r
e t u r n o f m o n e y
This function is used for enabling the return of the amount paid in
the event the selected product is not detected by the photocells.
2.2.2.3
e
m P t y s e l e c t I o n c o n t r o l
This function is used for disabling the selection that recorded a pho-
tocell error, i.e. failed product dispensing/detection.
2.2.3
d
I s P e n s I n g c o m P a r t m e n t l o c k P a r a m e t e r s
2.2.3.1
oP e r a t I n g m o d e
The dispensing compartment can be tted (as standard feature or
as optional according to the model) with a lock device.
This function is used for deciding whether leaving the dispensing
compartment “always free” or “unlock it with dispensing”.
2.2.3.2
u
n l o c k t I m e
With this function it is possible to program the time (1 minute min to
10 minutes max) when the dispensing compartment must remain
unlocked to allow the dispensing of the selected product.
This function is active only if the mode “unlock for dispensing” was
selected in the previous function.
2.2.2 - PHOTOCELL PARAM.
2.2.2
Ph o t o c e l l P a r a m e t e r s
2.2.3.3 - OUT Of SERV.TiME
2.2.3.3
ou t o f s e r v I c e t I m e
With this function it is possible to place the machine out of service
for a programmable time (1 minute min to 10 minutes max) in the
event the door stays open.
2.2.3.4 - OUT SER. if OPEN
2.2.3.4
ou t o f s e r v I c e I f o P e n
By enabling this function, the machine is placed out
of service if the lock device is always closed during
dispensing.