P2125EN00
01 - 2008
20
2.3 - COLD PARAMETERS
2.3.1 - TEMPERATURE
2.3.2 - DEfROSTiNG
2.3.3 - EN. COLD UNiT
2.3.4 - fOOD SAfE. T.EN.
2.3
co l d P a r a m e t e r s
2.3.1
te m P e r a t u r e
With this function the machine internal temperature during normal
operation can be set directly in °C (3.5°C to 20°C, 8°C by default).
The cooling unit starts/stops when the dierential deviation of the
set temperature is 2°C.
2.3.2
d
e f r o s t I n g
Defrosting involves switching o the cooling unit, regardless of the
set temperature, for 20 minutes.
With this function it is possible to se a time interval between defrost-
ing cycles, the value can be programmed from 0 to 99 hours (set to
6 hours by default); this time interval will be determined according to
the relative humidity and the frequency of door openings.
With the timing set to 0 the function is disabled.
2.3.3
e
n a b l I n g t h e c o o l I n g u n I t
With this function the cooling unit operation can be disabled. After
modigying this setting, the change will apply when restarting the
machine.
2.3.4
e
n a b l I n g t h e f o o d c o n t r o l
The machine can be pre-set for handling the dispensing of refriger-
ated food in the “food” version.
This function, enabled by default in the “food” models, activates the
safety temperature control and allows the denition of which trays
are preset for “food” control.
The machine can be converted for dispensing snack products only;
by disabling this function, the product temperature control is non
longer performed.
2.3.5 - TEMP. RECORDiNG
2.3.5
te m P e r a t u r e l o g
The internal temperature is stored every 10 minutes.
With this function, it is possible to read the date, time and stored
temperature.