STEP 9
Reset procedure deletes door travel parameters (step 6) and
alladvancedfunctions(step12).Itcanbeperformedincaseof
programmingmistakesanditbringstheAVIO500controlboard
tofactorysettings.
STEP 10
9.8
9.8
9.2
9.2
9.1
9.5
9.6
9.7
9.4
9.3
37
Thecontrolunitisprearrangedforinterfacingwithdifferentdevic-
esdedicatedtosystemcontrol,systemsafetyandotheraddition-
alfunctions.Belowisalistoftheirconnectionsandcorresponding
functions.
10.1 – TRANSFORMER
Standardtransformerofthesystem(suppliedandconnected)is
230V
*(primary)to0-24V (secondary)tothecontrolunit.
10.2 – MOTOR
Themaximumconnectableloadis100W(max3A)permotor.
RESET PROCEDURE
DEVICES CONNECTABLE TO THE CONTROL UNIT
ACTION RESULT
01. PRESS THE STARTBUTTONFOR8SECOND AllLEDflash
02. RELEASE STARTBUTTON AllLEDcontinuetoflash
03. PRESS THE STARTBUTTONFOR3SECOND AllLEDlightupinseries
04. RESETISNOWCOMPLETED
Thered“ERROR”LEDlightsflashes3times
continuosly
05.
ANEWPROGRAMMINGOFTHEAUTOMATION’S
MOVEMENTSISREQUIRED
Thisresetdoesn’taffectmemorizedradiotransmitters (see
step5forradiotrasmittersmanagement).
10.3 – WARNING LIGHT
TERMINALS:11-12.
Thewarninglightisanaccessoryusedforsignalinganymovement
ofthegatedoor.
ItisarrangedtoconnecttheFL200ashinglight.
10.4 – CONTACT OF THE AUXILIARY “OUT1” OUTLET
TERMINALS:1-2.
TheOUT1outletisavolt-freecontact(relaycontact).Itisenabled
bythetransmitterbutton.Anaccessorywithamaximumvoltage
of24Vmax3Wcanbeconnected.
10.5 – SAFETY DEVICES
TERMINALS:4-9-10.
Controlunithastwosafetyinputsavailableforvoltagefree(dry
con-tact)connection(s).
“S2 Photo” CLOSING or OPENING/CLOSING PHASE SAFETY
DEVICES
Terminals 4,8 allow connection of safety devices active during
closingandopeningphase.Thisinputisnormallyclosed(NC).For
infra-redphotocellsandsafetyedgeswithmicro-switchcontact.
ThefactorywirebridgeconnectedtoS2Photomustberemoved
whenusingthisinput.
These devices intervene during the gate’s closing and opening
phaseaccordingtoDIPswitch4(seepar.4.1).
Inparticular:
DIP4settoON:
- duringtheclosingphasetheyinvertthemovementdirection
andre-openthedoorfully
- duringtheopeningphasetheyhavenoeffect
- withtheopeneddoortheylockclosingcommands
- withthecloseddoortheyhavenoeffect
DIP4settoOFF:
- duringtheclosingphasetheylockthemovementandre-open
thedoorfullywhenreleased
- during the opening phase they lock the movement and re-
openthedoorfullywhenreleased
- withtheopeneddoortheylockclosingcommands
- withthecloseddoortheylockopeningcommands
Figure38showexamples“PHR00”photocellconnections.
When multiple devices are connected on this contact,
20–English
English