10.2 – SELECTION OF THE TYPE OF DEVICES CON-
NECTED TO “S1 EDGE”
Default = “S1 Edge” set for devices with normally closed
contact (terminal 9)
Thisprocedureallowsforsettingthe“S1Edge”outputformanag-
ing8.2kOhmresistiveedges.
The control unit constantly veries the integrity of the edge by
10.3 – OTHER FUNCTIONS
To interrupt the following programming sequences at
any time, press the SET and RADIO buttons simultaneously
or wait 10 seconds.
ACTION RESULT
01. PRESS STARTBUTTONFOR3SECONDS
AlltheLEDsturnoff(ifnot,consult
Paragraph10.3.1)
02.
PRESS THE RADIOBUTTONFOR1SECONDandthenchooseoneofthe
following:
• S1 Edge = resistive edge > 03.a
• S1 Edge = device with normally closed contact (NC) > 03.b
03.a
S1 Edge = resistive edge:theyellow“set”lightisON.
Ifthesettingiscorrect,proceedtoitem05;otherwise,goto04.a
Thered“error”LEDturnsoninthefixed
mode
04.a
Device with normally closed contact (NC):
PRESS THE STARTBUTTONFOR1SECOND
Thered“error”LEDremainslitinthefixed
modeandtheyellow“Set”LEDturnsoff
OR
03.b
S1 Edge = device with normally closed contact (NC): theyellowLED
“set”lightisOFF.
Ifthesettingiscorrect,proceedtoitem05;otherwise,goto04.b
Thered“error”LEDturnsoninthefixed
mode
04.b
Stop the programming sequences:
PRESSBOTHTHESTARTANDRADIOBUTTONSFOR2SECONDS
Thered“error”LEDremainslitinthefixed
modeandtheyellow“Set”LEDturnson
05.
PRESS THE SETANDRADIOBUTTONS
SIMULTANEOUSLYORWAIT10SECONDSTOEXITTHEPROCEDURE
TheLEDsreturntothenormaloperation
conguration
ACTION RESULT
01. PRESS STARTBUTTONFOR3SECONDS AlltheLEDsturnoff
02.
PRESS THE SETBUTTONFOR1SECONDANDTHENSELECTONEOF
THEFOLLOWING:
• control unit block activated > 03.a
•controlunitblockdeactivated>03.b
03.a
Control unit block activated: yellow“set”LEDlight,red“radio”LEDlight
andred“error”LEDlightareON.
Ifthesettingiscorrect,proceedtoitem05;otherwise,goto04.a
04.a
Unlocking programming sequences:
PRESSBOTHTHESTARTANDRADIOBUTTONSFOR2SECONDS
Theyellowled“set”,theredled“radio” and
redled“start” go OFF
OR
03.b
Control unit block activated: yellow“set”LEDlight,red“radio”LEDlight
andred“error”LEDlightareOFF.
Ifthesettingiscorrect,proceedtoitem05;otherwise,goto04.b
04.b
Stop the programming sequences:
PRESSBOTHTHESTARTANDRADIOBUTTONSFOR2SECONDS
Theyellowled“set”,theredled“radio” and
redled“start” go ON
05.
PRESSBOTHBUTTONSSETANDRADIO
SIMULTANEOUSLYORWAIT10SECONDSTOEXITTHE
PROCEDURE
AlltheLEDsgobacktostandardbehavior
measuringtheresistancebetweenthetwodedicatedterminals.
In order to carry out the check on the safety devices,
the connected edges must be of the resistive type with 8.2
kOhm.
10.3.1 – ACTIVATING/DEACTIVATING THE CONTROL
UNIT PROTECTION DEVICE
Default = control unit protection device not active.
This programming sequence allows for locking all control unit
programmingsequencesandthesettingsadjustablethroughthe
dip-switches.Toperformanewprogrammingsequenceormake
adip-switch/trimmermodicationeffective,theprotection must
bedeactivated.
English–23
English