EasyManua.ls Logo

Nice D-PRO AUTOMATIC NDCC1000 - Position Fine Adjustment; Setting Opening and Closing Positions with; Mechanical Limit Switch

Nice D-PRO AUTOMATIC NDCC1000
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
16 – English
3.12.1. Position ne adjustment
After learning the positions, if the set limit stop is not in the desired position, the
opening and closing limits can be adjusted:
• on DIP switch 3 (TABLE 11A)
in parameters P10-P11 (TABLE 11B)
without having to set the positions again.
Proceed as follows:
TABLE 11A
Phase
Operation to be performed
using
DIP switch 3
Graphical description
1 Set all DIP switches to OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
2
Open or close the door fully de-
pending on which limit you wish
to adjust
/
3 Set DIP switch 3 to ON
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
4
The display shows “0” and a
dash:
top if the door is open
bottom if the door is closed
5
Use the rear buttons to increase
(raise) or decrease (lower) the
limit position
/
6 Set all DIP switches to OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
7
Give a full open-close or close-
open command (depending on
where position was changed).
Check the door is higher/lower
than before
/
8
If the new position is still not as desired, repeat the procedure
from the beginning
TABLE 11B
Phase
Operation to be performed
using parameters P10 and
P11
Graphical description
1 Set all DIP switches to OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
2 Set DIP switch 1 to ON
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
3
Scroll to parameter P10 or P11
using the rear buttons
/
4 Set DIP switch 4 to ON
ON
1 2 3 4
OFF
5
The displays shows a 4-digit
number indicating:
P10 = maximum opening
position
P11 = maximum closing
position
6
Use the rear buttons to increase
(raise) or decrease (lower) the
limit position
/
7
Once the change has been
made, set all DIP switches to
OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
8
Give a full open-close or close-
open command (depending on
where position was changed).
Check the door is higher/lower
than before
/
9
If the new position is still not as desired, repeat the procedure
from the beginning
3.12.2. Setting opening and closing positions with MECHANICAL
LIMIT SWITCH
Two positions can be programmed, as described below:
TABLE 12 - Setting positions with mechanical limit switch
Position Meaning
Opening
Maximum opening position.
The door stops on reaching this position.
Closure
Maximum closing position.
The door stops on reaching this position
WARNING! – Before starting to move the door, make sure it is at least
50 cm above the ground.
Proceed as follows to set the positions with mechanical limit switch:
TABLE 13
Phase Operation to be performed Graphical description
1 Set all DIP switches to OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
2
Use the front button to
move the door to the desired
maximum opening position
3
a) Set contact cam 1 GREEN
E
to trigger the limit switch
b) Tighten fastening screw “A”
c) For ne adjustment use
screw “B”
see g. 21
4
Use the front button to move
the door to the desired
maximum closing position
5
a) Set contact cam 3 WHITE
E
to trigger the limit switch
b) Tighten fastening screw “A”
c) For ne adjustment use
screw “B”.
see g. 21
21
6 WHITE
CLOSING additional limit switch 1
5 GREEN
OPENING additional limit switch 1
4 RED
CLOSING safety limit switch
3 WHITE
CLOSING limit switch
2 RED
OPENING safety limit switch
1 GREEN
OPENING limit switch
P2P2P1P1SESE
EE
P1P1SESE
EE
B A
Safety limit switches 2
SE
and 4
SE
(RED, g. 21) are set at the factory to
closely follow the operating limit switch.

Table of Contents