5.2 Inverter setting parameter table – “U” series
Number Name Unit
Minimum value Maximum value
Default EE_1 Default EE_2 Default EE_3
Maintenance
1 Type of device Number - - - - -
2 Version (number) Number - - - - -
3 Version (date) Number - - - - -
4 Version (year) Number - - - - -
5 Memory of detected short-circuits Number 0 30 0 0 0
Speed
10 Slow (or creep) frequency Hz 2 187 19 20 17
11 Opening frequency Hz 2 187 60 50 70
12 Slow closing frequency Hz 2 187 35 30 45
13 Fast closing frequency (see also P59) Hz 2 187 60 50 50
Motor power management
20 Minimum frequency Hz 2 20 10 5 10
21 Minimum voltage Volt 10 69 69 20 23
22 Nominal frequency Hz 40 187 50 40 47
23 Emergency nominal frequency Hz 30 187 42 40 46
24 Maximum absorbed current for each motor phase 1/10 A 3 13.5 13.5 13.5 13.5
25 Injection of a DC current Number 1000 2500 1000 1000 1000
26 Duration of DC current injection Sec 100 600 600 600 600
Ramps
30 Acceleration ramp for opening manoeuvre 1/10 Sec 2 50 4 10 15
31 Acceleration ramp for closing manoeuvre 1/10 Sec 2 50 4 10 10
32 Deceleration ramp for opening manoeuvre 1/10 Sec 2 50 3 3 3
33 Deceleration ramp for closing manoeuvre 1/10 Sec 2 50 3 3 3
34 Deceleration ramp for stop 1/10 Sec 2 50 3 3 1
Brake management
40 Brake deactivation frequency Hz 0 50 Not managed 7 11
41 Brake activation frequency Hz 0 50 Not managed 7 12
Inverter monitoring
50 Inverter power voltage Volt - - - - -
51 Inverter temperature (NTC) Deg - - - - -
P70 Door operation selection Number 0 4 1 3 3
U11
U21
U10
U20
U34
U32
U30
P55
U11
U21
U10
U20
U34
U33
U31
P56
Opening time at cruising speed
Closing time at cruising speed

Table of Contents