English – 27
5.3 Service parameter table - “C” series
Parameter
number
Name
Unit
Minimum
value
Maximum
value
Default value
From version
1 Code entry for control unit unlocking Number 0 9999 0 0.40
2
Code saving for control unit locking/
unlocking
Number 0 9999 0 0.40
3
Software identication number (must be
410)
Number ro - 410 0.40
4 Software subversion (must be 400) Number ro 1000 - 0.40
5
Lock set by service
0 = No lock set
1 = Lock set
Number 0 1 0 0.40
6 Direction monitoring tolerance Number 1 20 5 0.69
7
Options relating to F24 error
0 = Complete voltage control
1 = Control suppressed when door in
motion
2 = Control completely suppressed
Number 0 2 1 0.72
8
Options relating to F6 error
0 = No change
1 = Direction of rotation control
deactivated
Number 0 1 0 0.89
9 Waiting time for direction change relays ms 2 100 10 1.31