EN
6 – English
1. PRODUCT DESCRIPTION AND INTENDED USE
1
• NDCC1000 is a control unit designed to operate rolling shutters and
sectional doors with three-phase 3x400 Vac motors equipped with Nice
encoders or mechanical limit switches.
• NDCC1100 is a control unit designed to operate high speed doors with
HDFI single-phase motor with inverter equipped with Nice encoders.
• NDCC1200 is a control unit designed to operate sectional doors with
single-phase 1x230 Vac motors equipped with Nice encoders or
mechanical limit switches.
TABLE 1 - Types of connection motor
Model Type of door Connection
Max.
power
NDCC1000
Rolling shutters and
sectional doors
Three-phase motors
with and without brake
2.2kW
NDCC1100 High speed doors
Motors with inverter
and brake
2.2kW
NDCC1200 Sectional doors
Single-phase motors
with start and run
capacitors
2.2kW
All control unit models can be connected to any common safety device.
To open and close a door, simply use the:
• specic button installed on the cover;
• external button;
• radio receiver.
WARNING! – Any use other than that described in this chapter and under
environmental conditions other than those specied in this manual is to
be considered improper and prohibited!
2. PRODUCT INSTALLATION
2.1 Installation criteria and special warnings in relation to
essential requirements
Carry out the installation while carefully following all the instructions described
in chap. “2. PRODUCT INSTALLATION” on p. 6 and in chap. “4. TESTING
AND PUTTING INTO SERVICE” on p. 18.
Ensure that an adequate maintenance plan is put in place (see "4.2 Putting into
service" on p. 18).
2.2 Pre-installation checks
Before installation, check the integrity of the control unit components, the
suitability of the chosen model and the suitability of the installation site:
• Check that all the material to be used is in excellent condition and suitable for
the intended use.
• Check that all conditions of use are within the product's use limitations (see
"2.3 Product use limitations") and within the limits of the values given in chap.
7. PRODUCT SPECIFICATIONS" on p. 30.
• Check that the chosen installation site is compatible with the overall
dimensions of the product (g.1).
• Ensure that the surface chosen for installing the product is solid and can
guarantee stable installation.
• Check that the fastening area is not subject to ooding; if necessary, install the
product adequately raised off the ground.
• Check that the space around the product allows easy and safe access.
• Check that all electrical cables to be used are of the type listed in "TABLE
3 - Electrical cable specifications".
2.3 Product use limitations
The product may only be used as stated in "TABLE 2 - Use limitations".
WARNING! – The control units described in this instruction manual may
NOT be used in areas at risk of explosion.
TABLE 2 - Use limitations
Model Central power supply Type of motor (*)
NDCC1000
Three-phase 3x400 Vac
50/60Hz
Three-phase 3x400 Vac 50/60Hz
with Nice encoder or mechanical
limit switches
NDCC1100
Single-phase 1x230 Vac
50/60Hz
Single-phase with inverter 3x230
Vac
50/60Hz with Nice encoder
NDCC1200
Single-phase 1x230 Vac
50/60Hz
Single-phase 1x230 Vac
50/60Hz and start and run
capacitors,
with Nice encoder or mechanical
limit switches
(*) Subject to the corresponding use limitations