SM-Applications Modules & Motion Processors User Guide 35
Issue Number: 4
Safety
Information
Introduction Installation
Getting
Started
Parameters
DPL
Programming
Communications
Freeze and
Marker
CTSync
Inter-option
Synchronization
Diagnostics
Migration
Guide
Quick
Reference
Index
Defines the action taken if a user DPL program attempts to write an out of range value
to a parameter. When set at 1, a run-time trip will occur (number 44); when set at zero
the value will automatically be limited to the maximum/minimum of that parameter
When set it enables the DPL program watchdog function. The DPL WDOG command
must then be executed every 200 ms. This can be used to protect the program against
malfunction. If the command is not executed within a 200 ms time period the drive will
trip on
SLx.tO. Please note that the WDOG command must also be executed once for
the watchdog to be enabled. This is normally executed at the end of the Initial task.
Pr 81.16 Encoder Data Update Rate
Access RW Range 0-3
Default 0 Update Rate Initialization
Display Description
0
APC data and menu 90 encoder parameters are
updated every 250 µs.
1
APC data and menu 90 encoder parameters are
updated immediately prior to every POS task.
2
APC data and menu 90 encoder parameters are
updated immediately prior to every CLOCK task.
3
APC data and menu 90 encoder parameters are
never updated. If these are never updated, more
processor resource will become free.
Apps Apps Lite Apps Plus Lite V2 ST Plus ST Indexer
Pr 81.17 Enable Parameter Over-range Trips
Access RW Range 0/1
Default 0 Update Rate Initialization
Apps Apps Lite Apps Plus Lite V2 ST Plus ST Indexer
Pr 81.18 Watchdog Enable
Access RW Range 0/1
Default 0 Update Rate Initialization
Apps Apps Lite Apps Plus Lite V2 ST Plus ST Indexer