EasyManua.ls Logo

Nidec SM-Applications Series - Page 34

Nidec SM-Applications Series
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34 SM-Applications Modules & Motion Processors User Guide
Issue Number: 4
Defines the scheduling rate for the POS tasks to suit the application performance and
the resource needed to run the user DPL program. The following values are defined:
Set this parameter in order for the user DPL program to automatically run at power-on/
reset. If this is changed and the new setting needs to be used on power-up ensure that
a
drive parameter save is performed.
Setting this parameter to 1 will cause the drive to trip when certain run-time errors occur
within the Second Processor user DPL program.
For more information, see section 11.1 Run-time Errors on page 112.
When this parameter is 0, the module will be reset when a drive trip is cleared. When set
to 1 the module will be unaffected by a drive trip reset (i.e. continue running)
Pr 81.12 POS task scheduling rate
Access RW Range 0 to 6
Default 0 Update Rate Initialization
Display Value Description
diSAbled 0 Disabled
0.25 1 250µs
0.5 2 500µs
131ms
242ms
454ms
868ms
Apps Apps Lite Apps Plus Lite V2 ST Plus ST Indexer

With the Unidrive SP version 01.03.00 and earlier, the display will not show the actual
rate, but its aliased number. For instance 250 µs will be shown on the display as 1.
Pr 81.13 Auto-run Enable
Access RW Range 0/1
Default 1 Update Rate Initialization
Apps Apps Lite Apps Plus Lite V2 ST Plus ST Indexer

Pr 81.14 Global Run-time Trip Enable
Access RW Range 0/1
Default 0 Update Rate Initialization
Apps Apps Lite Apps Plus Lite V2 ST Plus ST Indexer

Pr 81.15 Disable Reset on Trip Cleared
Access RW Range 0/1
Default 0 Update Rate Initialization
Apps Apps Lite Apps Plus Lite V2 ST Plus ST Indexer

NOTE

Table of Contents

Related product manuals