Chapter 1 System Configurations and Part Names
1.4 Name of Each Part
1-41
TI-TIRF illuminator unit
A.
S.
ND4
FILTERND8
N
D
4
N
D
8
N
D
16
N
D
8
N
D
2
CAUTION

CLASS 3B
LASER RADIATION WHEN OPEN
AVOID EXPOSURE TO THE BEAM
VORSICHT

LASERSTRAHLUNG
KLASSE 3B,
WENN ABDECKUNG GEFFNET
NICHT DEM STRAHL AUSSETZEN
CA
UTIO
N

C
L
ASS
3B
LA
SER
R
ADIATI
O
N
WHE
N
OPEN
AV
O
I
D
EXPOSURE TO TH
E BE
AM
V
O
RS
ICHT

LA
SERS
T
R
A
H
LUNG
K
LA
S
SE 3B
,
WE
N
N
ABDECKUNG G
E

F
FNET
NI
CHT
D
EM
ST
RAH
L
AUSSETZEN
LA
S
ER
R
ADIATION W
H
EN OP
E
N
AVOI
D EXPOSURE TO THE BEAM
CAUTI
ON

CLASS 3B
NIC
HT
D
EM STR
AHL A
U
S
SETZEN
KLASS
E 3
B,
WENN
ABD
E
C
K
UNG
G
E
FFNE
T
V
O
R
S
I
C
H
T 
LASE
R
S
T
R
A
H
LUNG
Figure 1.4-3
Parts used in the TIRF microscopy operation
(1) Optical fiber
(2) Laser position adjustment knob
(for right and left adjustment)
(3) Laser position adjustment knob
(for forward and backward adjustment)
(4) ND filter sliders
(5) Mirror switching lever
Push in: TIRF (60%) and Epi (40%)
Pull out: TIRF (100%)
(6) Focal point adjustment knob
(7) Condenser lens locking screw
Parts used in the epi-fl microscopy operation
(8) Field diaphragm centering screws
(9) Field diaphragm open/close lever
(10) Aperture diaphragm centering screws
(11) Aperture diaphragm open/close lever
(12) ND filter sliders
(13) Excitation filter slider
(14) Connector for the HG fiber light source
adapter
(1) Optical fibe
(2) Laser position adjustment knob
(for right and left adjustment)
(3) Laser position adjustment knob
(for forward and backward
adjustment)
(14) Connector for the
HG fiber light
source adapter
(13) Excitation filter slider
(12) ND filter slider
(11) Aperture diaphragm
open/close lever
(10) Aperture diaphragm
centering screws
(5) Mirror switching lever
Push in: TIRF (60%) and Epi (40%)
Pull out: TIRF (100%)
(4) ND filter sliders
(6) Focal point adjustment knob
(7) Condenser lens locking screw
(9) Field diaphragm open/close lever
(8) Field diaphragm centering screws

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nikon Eclipse TI-TIRF-E and is the answer not in the manual?

Nikon Eclipse TI-TIRF-E Specifications

General IconGeneral
BrandNikon
ModelEclipse TI-TIRF-E
CategoryLaboratory Equipment
LanguageEnglish