Revision 2
• Avoid personal injury. Use a chain hoist, or get assistance, when lifting components that
weigh
50
lb. (23 kg) or more. Make sure all lifting devices (chains, hooks, or slings) are
in good condition and are
of
the correct capacity. Make sure hooks are positioned
correctly. Always use a spreader bar when necessary. The lifting hooks
must not be
side loaded.
•
To
avoid burns, be alert for hot parts on components that have just been turned off.
• Always use tools that are in good condition. Make sure you understand how to use them
before performing any preventive maintenance work.
• Use ONLY genuine NLB replacement parts.
• Do not make any unauthorized alterations
to
the equipment or components.
• Do not attempt pressurization
of
the power end with dry gas to exclude contaminants
without a special oil level indicator. With a standard indicator, all oil will be lost
through the vent hole in the top
of
the indicator.
• Adhere to the preventive maintenance intervals to ensure proper operation
of
high
pressure water jetting unit.
II.
Trouble-Shooting Procedures
The NLB Corporation Models 1312D, 1012D, 812D, 612D, 512D, 412D, 3.512D, 312D,
1060D, 860D, & 760D high pressure water jetting units are relatively straightforward
operating machines. For this reason, ordinary trouble-shooting methods will suffice in
almost every case.
A.
Trouble-Shooting Tips
The following trouble-shooting tips are offered
to
assist the technician in tracking down
problems:
• Take a few minutes to carefully listen to the unit and observe
it
in operation. Learn to
recognize the normal noises and operating conditions
of
the unit. This will enhance
your ability
to
notice any unusual machine behavior.
© Copyright December, 1999 NLB Corporation
6-3