Parameter Reference
Parameter Reference
120 121
Sustain level (target of the second Decay segment).
Time of the (exponential) Release segment in milliseconds
(infinite at maximum).
Velocity influence on the Release time. The value represents
the logarithmic amount of the reduction of the Release time
by high Note-O velocities.
Influence of the key velocity on the peak, breakpoint and
sustain levels of the envelope [maximum dynamic range in
dB].
Key tracking of the envelope’s peak, breakpoint and sustain
levels [dB per semitone].
Positive values: higher levels for higher notes (+1.0 = +12 dB
per octave).
Negative values: lower levels for higher notes (-1.0 = -12 dB
per octave). Origin at C3 = 60 semitones.
Key tracking of the attack, decay and release times. The
value determines how much shorter the times get for higher
notes.
Envelope A
Time of the (polynomial) Attack segment in milliseconds.
Velocity influence on the Attack time. The value represents
the logarithmic amount of the reduction of the Attack time
by high Note-On velocities.
Curvature of the (polynomial) Attack segment.
(negative: decelerating slope, zero: linear, positive: acceler-
ating slope)
Time of the first (linear) Decay segment in milliseconds.
Level of the Breakpoint between the two Decay segments.
Time of the second (exponential) Decay segment in millisec-
onds.
Envelope A
Envelope A