Loading...
System Setup
3-7
Part 1604857-04
E 2014 Nordson Corporation
9
4*
6*
12
1
5
3
7
2*
2
Create Service Loop Here
Figure 3-8 Encore LT Gun Pickup Tube and Pump Installation
1. Bulkhead union
2. 6-mm black fluidizing air tubing*
3. Hose clamp
4. Blue 8-mm atomizing tubing*
5. Velcro straps
6. Black 8-mm flow-rate tubing*
7. Powder hose
9. Blue 6-mm fluidizing tubing
12. Grommet
Note: * Create service loop as noted before securing tubing to arm with straps.
WARNING: The black fluidizing air tubing (2), the pickup tube connector,
and the bulkhead union (1) are conductive and provide a ground path to the
cart. Do not replace these components with non-conductive components.
Refer to Parts for replacement tubing.
NOTE: The pump is equipped with quick-connect couplings that allow you
to quickly disconnect the air tubing when cleaning or repairing the pump.
Pull back on the knurled coupling rings to uncouple them.