System Setup
3-6
Part 1604857-04
E 2014 Nordson Corporation
VBF System Setup (contd)
4. See Figure 3-7. Swing the tube bracket out of the way and install the
pickup tube (1) in the arm.
5. Install the pump (3) into the pump mount (2) with a slight twisting
motion.
2
1
3
4
Figure 3-7 Encore LT Gun Pickup Tube and Pump Installation
1. Pickup tube
2. Pump
3. Tube bracket 4. Pump mount
6. Unpack the air tubing, powder hose, clamps, and Velcro straps shipped
with the system.
7. See Figure 3-4. Plug the shorter lengths of the tubing into the controller:
S 8-mm blue atomizing air tubing (4)
S 8-mm black flow-rate air tubing (6)
S 6-mm blue fluidizing air tubing (9)
8. See Figure 3-8. Route the tubing (4, 6, 9) through the grommet in the
front panel of the cart tower as shown.
9. Connect the tubing and powder hose as shown:
S 8-mm blue atomizing air tubing (4) to the pump top fitting
S 8-mm black flow-rate air tubing (6) to the pump bottom fitting
S 6-mm blue fluidizing air tubing (9) to the bulkhead union (1)
S 6-mm black fluidizing air tubing (2) to the union and pick-up tube.
S powder hose (7) to the pump—secure with hose clamp (3)
NOTE: Before securing the pump and fluidizing air tubing to the pickup
arm, provide a service loop in the tubing to allow for lifting and removing the
pickup tube and pump from the arm without disconnecting the tubing.
10. Secure the tubing to the arm with blue Nordson Velcro straps (5).