ProBlue Fulfill Integrated Fill System
11
Part 1101094_02
E 2012 Nordson Corporation
Table 1 Installation Clearances (see Figure 5)
Item Description Required Clearance
A
Thedistancefromtheoutsideedgeofa
5
/
16
-in. Nordson hose
to the front face of the melter when a short 90-degree hose
fitting is used to connect the hose to the melter
P4 = 370 mm (14.5 in.)
P7 = 370 mm (14.5 in.)
P10 = 391 mm (15.4 in.)
B
The clearance required to open the pump enclosure door P4 = 243 mm (9.6 in.)
P7 = 243 mm (9.6 in.)
P10 = 268 mm (10.55 in.)
C
Thedistancefromthemelterbasetothetopsurfaceofthetank
lid when it is closed.
P4 = 567.4 mm (22.34 in.)
P7 = 565.2 mm (22.25 in.)
P10 = 654.3 mm (25.76 in.)
D
The clearance required on the left side of the melter to open the
electrical enclosure door or remove a hose/gun module.
P4 = 648 mm (25.5 in.)
P7 = 711 mm (28.0 in.)
P10 = 714 mm (28.1 in.)
E The clearance required to access the fill sys tem filter. All = 50.8 mm (2.00 in.)
F
The clearance required to open the tank lid. P4 = 895.9 mm (35.27 in.)
P7 = 977.7 mm (38.49 in.)
P10 = 974 mm (38.35 in.)
559 mm
(22 in.)
940 mm
(37 in.)
534 mm
(21 in.)
559 mm
(22 in.)
1397 mm
(55 in.)
Figure 6 Adhesive storage bin clearances