Troubleshooting
6-43
Part 1024496_06
2014 Nordson Corporation
Problem
Turn on or adjust the plant air
pressure.
+
+
Is air being supplied to the top of
the pump?
Is 24 VDC being supplied to the
solenoid valve (wire harness
leads 9 and 10)?
Replace the pneumatic
assembly.
P/N 1028307.
+
+
Are the yellow and green air lines
to the pneumatic assembly
connected properly?
See Figure 6-4.
Do the wires at Pins 9 and 10 on
the J7 wire harness lack
continuity?
Connect securely. See Figure
6-2.
Replace the J7 wire harness.
P/N 1024600.
Connect securely.
Replace the main board.
P4/P7 P/N 1028322.
P10 P/N 028323.
+
Is the air supply to the melter
turned off or is the plant air
pressure low?
+
Is the operating air pressure set
correctly?
Refer to Section 4.
Adjust the operating air
pressure for the current
manufacturing process.
Continued
on next
page....
Starting conditions:
No faults >
Ready LED is illuminated >
No hot melt output from all guns >
Pump has stopped >
Pump LED is illuminated >
Tank set-point temperature is OK >
Pump is not controlled by a remote input
T.4.2