Operating Parameters
B-5
Part 1024496_06
2014 Nordson Corporation
10
Enable or Disable the Melter Password
Description:
Activates or deactivates the melter password. When password
protection is activated, component set-point temperatures or melter
operating parameters cannot be changed until a valid password is
entered using parameter 0.
Value:
0 (disabled)
1 (enabled)
Resolution:
Default Value:
0
Format:
Use:
A password must first be created using parameter 11 before it can be
enabled or disabled using parameter 10.
11
Create Password
Description:
A user-defined password that prevents unauthorized changes to
operating parameters or set-point temperatures.
Value:
0 to 9999
Resolution:
1
Default Value:
5000
Format:
Use:
Refer to Section 4, Operation Enter the Melter Password.
NOTE: When the password is created and enabled, parameter 10 will
not appear again in the right display until the password is entered.
14
External Communications Lock-out
Description:
Used as a safety feature when performing maintenance on the melter.
Prevents external control of the melter through standard or optional
inputs/outputs or network communications (optional)
Value:
0 (disabled)
or
1 (enabled)
Resolution:
Default Value:
0 (disabled
Format:
Use:
Set parameter to 1 (enabled) before performing any maintenance on the
melter. When enabled, all external control of the melter stops until the
parameter is once again set to 0 (disabled).