Mount the Melter to the Transformer
1. Coil the three transformer wire harnesses and temporarily stow them in
the area of the terminal block.
See Figure E‐7.
CAUTION! Ensure that the transformer wire harnesses are not pinched
between the transformer and the melter.
2. Set the melter down onto the transformer so that the four tabs on the
transformer enter the slots in the base of the melter.
3. Secure the melter to the transformer using the four M5 X 10 screws that
are provided in the installation kit.
See Figure E‐8.
4. Connect the ground lead from the melter to the ground connection on the
transformer chassis.
Figure E‐7 Mounting the melter to the transformer