P10 6‐hose manifold guard
Installation
3-21
Part 1024496_06
2014 Nordson Corporation
CAUTION! Failure to connect a hose to port 1 may create spaces within the
manifold where hot melt will not circulate. The presence of these spaces can
result in the build‐up of hot melt char, which can lead to an increase in the
frequency of melter maintenance.
Use the 6‐hose manifold guard that is shipped with all P10 melters.
Instructions for installing the guard are provided with the guard.
Coordinate the connection of each hose with the receptacles on each
hose/gun module. For example, connect the cordset from the hose that is
connected to port 1 (marked) to receptacle 1.
Save all of the port plugs removed from the manifold. A port plug will
need to be reinstalled into the manifold if a hose is later removed.
Use the 45‐ or 90‐degree hose fittings provided in the installation kit.
NOTE: Only 90‐degree fittings are shipped with the P4 and P7 melters.
Figure 3‐8 Connecting a hose