Front Panel
Power Switch: Turns the UltimusV dispenser on and off.
RS‑232 Connector: Allows all dispensing parameters to be modified from a remote PC or PLC.
LCD Display: Shows data and system status as well the current function selected.
Function Buttons: Used to select items shown on the bottom of the LCD display above the individual function
buttons. The function of each key depends on the current screen display and / or mode.
Cycle Button: Initiates a dispense cycle.
Air Output Quick Connector: Syringe barrel adapter / Optimeter
connection.
ESD Jack: Standard 0.166" banana jack allows the user to connect grounding for ESD-sensitive equipment.
Numeric Keypad: Used to enter settings.
Scroll Keys: The arrow-shaped 2,4, 6, and 8 keys on the numeric keypad can be used for cursor scrolling as well as
data entry.
Easy Adjust Buttons: Adjusts dispense time or memory cell location.
Enter Key:
Confirms highlighted selection or data entered.
Features and Controls
Power
Switch
Function
Buttons
ESD Jack
Enter Key
RS-232 Connector
LCD Display
Air Output
Quick
Connector
Cycle Button
Numeric Keypad
Scroll Keys
Easy Adjust
Buttons