2.6.3.8 Trigger Value Read Command
This command returns the 5-digit trigger value of the current memory location.
Client command and data: (STX) + 04 + ER-- + C5 + (ETX)
The above text packet in hexadecimal format:
STX 0 4 E R space space C 5 ETX
0x02 0x30 0x34 0x45 0x52 0x20 0x20 0x43 0x35 0x03
NOTE: “D0” is the letter “D” followed by the digit “0.”
Return Format: D0TVttttt
ttttt: 5-digit trigger value. Range is 00000–99999.
EXAMPLE: If the trigger value is 100, the text packet received from the dispenser is:
(STX) + 09 + D0TV00100 + 88 + (ETX)
Length of the response text packet: Decimal 9 or hexadecimal 0x09
The above text packet in hexadecimal format:
STX 0 9 D 0 T V 0 0 1 0 0 8
0x02 0x30 0x39 0x44 0x30 0x54 0x56 0x30 0x30 0x31 0x30 0x30 0x38
8 ETX
0x38 0x03
2.6.3.9 Deposit Count Read Command
This command returns the current 7-digit deposit count that is stored in the dispenser.
Client command and data: (STX) + 04 + E9-- + DE + (ETX)
The above text packet in hexadecimal format:
STX 0 4 E 9 space space D E ETX
0x02 0x30 0x34 0x45 0x39 0x20 0x20 0x44 0x45 0x03
NOTE: “D0” is the letter “D” followed by the digit “0.”
Return Format: D0SCccccccc
ccccccc: 7-digit deposit counter. Range is 0000000 to 9999999.
EXAMPLE: If the deposit counter value is 1050250, the text packet received from the dispenser is:
(STX) + 0B + D0SC1050250 + 27 + (ETX)
The above text packet in hexadecimal format:
STX 0 B D 0 S C 1 0 5 0 2 5 0
0x02 0x30 0x42 0x44 0x30 0x53 0x43 0x31 0x30 0x35 0x30 0x32 0x35 0x30
2 7 ETX
0x32 0x37 0x03
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
69www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.