2.6.2.20 Set Trigger Value Command
This command downloads the 5-digit trigger value into the current memory location.
Client command and data: EQ--Tttttt
ttttt: Trigger Value. 00001–99999
EXAMPLE: If the trigger value is 1000, the text packet it: (STX) + 0A + EQ-- + T01000 + 74 + (ETX)
Length of this text packet: Decimal 10 or hexadecimal 0A
The above text packet in hexadecimal format:
STX 0 A E Q space space T 0 1 0 0 0 7
0x02 0x30 0x41 0x45 0x51 0x20 0x20 0x54 0x30 0x31 0x30 0x30 0x30 0x37
4 ETX
0x34 0x03
2.6.2.21 Set the Real Time Clock Command
This command sets the time for the real time clock on the dispenser.
Client command and data: EB--HhhMmmAMa
hh: Hours. 0–23 for 24 hour format, 1–12 for 12 hour format
mm: Minutes. 0–59
a: Hour format. 0 = AM, 1 = PM, 2 = 24 hour format
EXAMPLE: To set the time as 14:05 and the hour format to 24-Hour, the text packet is:
(STX) + 0D + EB-- + H14M05AM2 + A6 + (ETX)
Length of this text packet: Decimal 13 or hexadecimal 0D
The above text packet in hexadecimal format:
STX 0 D E B space space H 1 4 M 0 5 A
0x02 0x30 0x44 0x45 0x42 0x20 0x20 0x48 0x31 0x34 0x4D 0x30 0x35 0x41
M 2 A 6 ETX
0x4D 0x32 0x41 0x36 0x03
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
59www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.