2.6.3.14 Alarm Status Read Command
This command returns the status of each of the dispenser alarms.
Client command and data: (STX) + 04 + EL-- + CB + (ETX)
The above text packet in hexadecimal format:
STX 0 4 E L space space C B ETX
0x02 0x30 0x34 0x45 0x4C 0x20 0x20 0x43 0x42 0x03
NOTE: “D0” is the letter “D” followed by the digit “0.”
Return Format: D0INiPApAIa
i: input Alarm Status: 1= Alarm is set, 2= No alarm
p: Pressure Alarm Status
a: Auto Increment Alarm Status
EXAMPLE: If the Pressure Alarm Status is “Alarm is set,” the text packet received from the dispenser is:
(STX) + 0B + D0IN2PA1AI2 + D3 + (ETX)
Length of the response text packet: Decimal 11 or hexadecimal 0B
The above text packet in hexadecimal format:
STX 0 B D 0 I N 2 P A 1 A I 2
0x02 0x30 0x42 0x44 0x30 0x49 0x4E 0x32 0x50 0x41 0x31 0x41 0x49 0x32
D 3 ETX
0x44 0x33 0x03