2.6.3.10 Real Time Clock Read Command
This command returns the current time of the real time clock on the dispenser.
Client command and data: (STX) + 04 + EE-- + D2 + (ETX)
The above text packet in hexadecimal format:
STX 0 4 E E space space D 2 ETX
0x02 0x30 0x34 0x45 0x45 0x20 0x20 0x44 0x32 0x03
NOTE: “D0” is the letter “D” followed by the digit “0.”
Return Format: D0HhhMmmAMa
hh: Hours. 0–23 for 24 hour format, 1–12 for 12 hour format
mm: Minutes. 0–59
a: Hour format. 0 = AM, 1 = PM, 2 = 24 hour format
EXAMPLE: If the current time on the dispenser is 14:25, the text packet received from the dispenser is:
(STX) + 0B + D0H14M25AM2 + F9 + (ETX)
The above text packet in hexadecimal format:
STX 0 B D 0 H 1 4 M 2 5 A M 2
0x02 0x30 0x42 0x44 0x30 0x48 0x31 0x34 0x4D 0x32 0x35 0x41 0x4D 0x32
F 9 ETX
0x46 0x39 0x03
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
70 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.