2.6.3.13 Alarm Options Read Command
This command returns the current settings of the dispenser alarm options.
Client command and data: (STX) + 04 + EJ-- + CD + (ETX)
The above text packet in hexadecimal format:
STX 0 4 E J space space C D ETX
0x02 0x30 0x34 0x45 0x4A 0x20 0x20 0x43 0x44 0x03
NOTE: “D0” is the letter “D” followed by the digit “0.”
Return Format: D0INiIOoILlPOpPLbAEeAOa
A “1” indicates the alarm feature is enabled. A “0” indicates the alarm feature is disabled.
i: Enable Input Alarm (IN)
o: Enable Output Of Input Alarm (IO)
l: Latch the Input Alarm (IL)
p: Enable Output of the Pressure Alarm (PO)
b: Latch the Pressure Alarm (PL)
e: Enable Auto Increment Alarm (AE)
a: Enable Output of the Auto Increment Alarm (AO)
EXAMPLE: If Enable Output of the Pressure Alarm (PO) and Latch the Pressure Alarm (PL) are enabled, the text
packet received from the dispenser is: (STX) + 17 + D0IN0IO0IL0PO1PL1AE0AO0 + BD + (ETX)
Length of the response text packet: Decimal 23 or hexadecimal 17
The above text packet in hexadecimal format:
STX 1 7 D 0 I N 0 I O 0 I L
0x02 0x31 0x37 0x44 0x30 0x49 0x4E 0x30 0x49 0x4F 0x30 0x49 0x4C
0 P O 1 P L 1 A E 0 A O 0
0x30 0x50 0x4F 0x31 0x50 0x4C 0x31 0x41 0x45 0x30 0x41 0x4F 0x30
B D ETX
0x42 0x44 0x03
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
73www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.