2.6.2.23 Operator Lockout Set Command (continued)
EXAMPLE: If the supervisor password is 0000 and if Dispense Time, Dispense Pressure, and Dispense Vacuum
need to be locked out, the text packet is:
(STX) + 39 + EG-- + PA0000DT1DP1DV1M0DC0DM0AI0AR0AL0MM0PU0VU0LA0CL0CO0AM0 + 79 + (ETX)
Length of this text packet: Decimal 57 or hexadecimal 39
The above text packet in hexadecimal format:
STX 3 9 E G space space P A 0 0 0 0
0x02 0x33 0x39 0x45 0x47 0x20 0x20 0x50 0x41 0x30 0x30 0x30 0x30
D T 1 D P 1 D V 1 M 0 D C
0x44 0x54 0x31 0x44 0x50 0x31 0x44 0x56 0x31 0x4D 0x30 0x44 0x43
0 D M 0 A I 0 A R 0 A L 0
0x30 0x44 0x4D 0x30 0x41 0x49 0x30 0x41 0x52 0x30 0x41 0x4C 0x30
M M 0 P U 0 V U 0 L A 0 C
0x4D 0x4D 0x30 0x50 0x55 0x30 0x56 0x55 0x30 0x4C 0x41 0x30 0x43
L 0 C O 0 A M 0 7 9 ETX
0x4C 0x30 0x43 0x4F 0x30 0x41 0x4D 0x30 0x37 0x39 0x03
2.6.2.24 Set Language Command
This command sets the language for the dispenser.
Client command and data: ED--LI: Language Index
0 = English
1 = French
2 = German
3 = Spanish
4 = Italian
5 = Chinese
6 = Japanese
7 = Korean
EXAMPLE: To set the language as Spanish, the text packet is: (STX) + 05 + ED-- + 3 + 9F + (ETX)
The above text packet in hexadecimal format:
STX 0 5 E D space space 3 9 F ETX
0x02 0x30 0x35 0x45 0x44 0x20 0x20 0x33 0x39 0x46 0x03
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
61www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.