Connect Power
1. Connect the power cord to the back of the dispenser.
2. Plug the power cord into your local power source.
3. Turn the power switch on the front panel to the on position.
Connect Foot Pedal
The UltimusV can be operated using the foot pedal provided, or by an external
device via a DB-15 connector.
1. Plug the foot pedal into the connector on the back of the dispenser.
2. You can also operate the UltimusV with an optional finger switch or a 5 to 24
VDC pulse.
Connect Air Input
NOTE: Clean, dry, filtered factory air is required to meet warranty. To ensure air
quality, install the five-micron filter regulator provided with the UltimusV.
1. Push one end of the air input hose into the Air In fitting on the back of the
dispenser.
2. Connect the other end of the air input hose to the filter regulator supplied
with the UltimusV dispenser.
NOTE: Input air should be set at least 1.0 bar (15 psi) — or more — higher
than dispensing pressure, up to a maximum of 0–7.0 bar (0–100 psi).
Connect Air Output
Push the connector on the adapter / Optimeter into the connector on the front of
the UltimusV and twist clockwise to lock.
Attach Syringe Barrel and Tip
1. Secure an EFD syringe barrel filled with your fluid to the adapter / Optimeter.
2. Replace the tip cap with an appropriate EFD precision dispense tip.
Initial Setup for Testing
Ultimus V High Precision Fluid Dispenser