2.6.2.22 Set the Real Time Date Command
This command sets the date for the real time clock on the dispenser.
Client command and data: EC--MmmDddYyy
mm: Months. 1–12
dd: Days. 1–31
yy: Years. 00–99
EXAMPLE: To set the date as 1st January 2022, the text packet is: (STX) + 0D + EC-- + M01D01Y22 + B4 + (ETX)
Length of this text packet: Decimal 13 or hexadecimal 0D
The above text packet in hexadecimal format:
STX 0 D E C space space M 0 1 D 0 1 Y
0x02 0x30 0x44 0x45 0x43 0x20 0x20 0x4D 0x30 0x31 0x44 0x30 0x31 0x59
2 2 B 4 ETX
0x32 0x32 0x42 0x34 0x03
2.6.2.23 Operator Lockout Set Command
This command updates the operator lockout settings. A “1” indicates that a feature is locked out. A “0” indicates
that the feature is not locked out.
Client command and data: EG--PAppppDTtDPpDVvMmDCcDMdAIaARuALbMMePUfVUgLAhCLjCOkAMn
pppp: 4-digit password. This needs to match the password set on the dispenser. The dispenser returns an error if
incorrect.
t: Lockout dispense time: “1”=lockout, “0”=enabled (DT)
p: Lockout dispense pressure (DP)
v: Lockout dispense vacuum (DV)
m: Lockout memory cell selection (M)
c: Lockout deposit counter selection (DC)
d: Lockout dispense mode change (DM)
a: Lockout Auto Increment Mode selection (AI)
u: Lockout Auto Increment Reset (AR)
b: Lockout Alarms Reset (AL)
e: Lockout Main Menu selection (MM)
f: Lockout Pressure Unit Menu selection (PU)
g: Lockout Vacuum Unit Menu selection (VU)
h: Lockout Language Menu selection (LA)
j: Lockout Set Clock / Date Menu selection (CL)
k: Lockout Set Communications Menu selection (CO)
n: Lockout Alarm Options Menu selection (AM)
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
60 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.