2.6.2.15 Deposit Count Clear Command
This command resets the deposit counter on the dispenser to all zeros.
Client command and data: (STX) + 04 + EA-- + D6 + (ETX)
The above text packet in hexadecimal format:
STX 0 4 E A space space D 6 ETX
0x02 0x30 0x34 0x45 0x41 0x20 0x20 0x44 0x36 0x03
2.6.2.16 Reset Auto Increment Command
This command resets the Auto Increment functions. The dispenser will set the Memory Address to the Start Address
Value, reset the counters, and clear the auto increment alarm. If the dispenser is not in counter or timer mode, the
dispenser returns a Failure Command (
A2) text packet.
Client command and data: (STX) + 04 + SE-- + C4 + (ETX)
The above text packet in hexadecimal format:
STX 0 4 S E space space C 4 ETX
0x02 0x30 0x34 0x53 0x45 0x20 0x20 0x43 0x34 0x03
2.6.2.17 Auto Increment Mode On / Off Command
This command enables or disables the Auto Increment Mode. When enabling the Auto Increment Mode, the
dispenser will enable to Count Mode.
NOTE: This command is not necessary to enable Auto Increment Mode. The Auto Increment Mode command
(2.6.2.18) can be used instead.
Client command and data: AI--i
i: Enable Command. 0=OFF, 1 = ON
EXAMPLE: To enable the Auto Increment Mode, the text packet is: (STX) + 05 + AI-- + 1 + A0 + (ETX)
The above text packet in hexadecimal format:
STX 0 5 A I space space 1 A 0 ETX
0x02 0x30 0x35 0x41 0x49 0x20 0x20 0x31 0x41 0x30 0x03
Appendix B — RS‑232 Protocol (continued)