2.6.3.3 Pressure Time Vacuum Read Command
This command returns the Dispense Pressure, Dispense Time, and Vacuum values of the specified address. This
command also update the LCD screen to the specified memory location.
Client command and data: E8ccc
ccc:
The 3-digit memory location from 0–399. The dispenser will automatically limit value to prevent any errors.
EXAMPLE: To read the pressure, time, and vacuum values in memory location #1, the text packet is:
(STX) + 05 + E8001 + 8D + (ETX)
NOTE: This command changes the current memory location in the dispenser as set in the command (e.g., 001 in
above example command), in addition to returning the values for pressure, time, and vacuum.
The above text packet in hexadecimal format:
STX 0 5 E 8 0 0 1 8 D ETX
0x02 0x30 0x35 0x45 0x38 0x30 0x30 0x31 0x38 0x44 0x03
NOTE: “D0” is the letter “D” followed by the digit “0.”
Return Format: D0PDppppDTtttttVCvvvv
pppp: The 4-digit pressure setting excluding the decimal point. This is a unitless value. The valid pressure ranges
and decimal point are determined by the pressure units currently selected in the dispens
ttttt: The 5-digit dispense time value excluding the decimal point. The valid range is 0.0000 to 9.9999 seconds.
vvvv: The 4-digit vacuum setting excluding the decimal point. This is a unitless value. The valid vacuum ranges and
decimal point are determined by the vacuum units currently selected in the dispenser.
Interpreting the pressure setting from the return feedback value:
Pressure Unit
Value Received from the
Dispenser (pppp)
Pressure Setting
psi 0000–1000 0.0–100.0 psi
kPa 0000–6895 0.0–689.5 kPa
Bar 0000–6895 0.000–6.895 bar
Interpreting the vacuum setting from the return feedback value:
Vacuum Unit
Value received from Ultimus
V (vvvv)
Vacuum Setting
H
2
O 0000–0180 0.0–18.0 H
2
O
kPa 0000–0448 0.00–4.48 kPa
Hg 0000–0132 0.00–1.32 Hg
mmHg or Torr 0000–0336 0.0–33.6 mmHg
EXAMPLE: If the requested memory location is 1, the pressure setting at the memory location is 50.0 psi, the time
setting is 1.0055 s, and the vacuum setting is 10.0 H
2
O, the text packet received from the dispenser is:
(STX) + 15 + D0PD0500DT10055VC0100 + E0 + (ETX)
Length of the response text packet: Decimal 21 or hexadecimal 0x15
Appendix B — RS‑232 Protocol (continued)