12.5 Optical
Brightness is measured according to ISO/IEC 21118:2012 (minimum brightness >80% of average production
values).
PARAMETER
MIN.
TYP.
MAX.
UNIT
COMMENT
Initial
brightness
(uncorrected)
2,100
2,300
2,250
2,500
-
-
ANSI Lumen
RGB mode WQ
RGB mode WU
Measured
mode
White point
(uncorrected)
x = 0.270
y = 0.300
x = 0.285
y = 0.330
x = 0.300
y = 0.360
CIE1931
Measured
mode
White point
(corrected)
x = 0.290
y = 0.320
x = 0.295
y = 0.325
x = 0.300
y = 0.330
CIE1931
Desired mode
Brightness
maintenance
50
80
-
%
At 50,000
hours of initial
brightness
Contrast B/W
static
-
1,600:1
8,000:1
-
-
Iris open, iris
closed, at
100% power
Contrast B/W
static
-
>5,000,000
-
-
Iris closed, at
X% power
Contrast B/W
ANSI
-
340:1
Iris open, at
100% power
12.6 Audible noise
The audible noise is measured according to ISO/IEC 21118:2012, average at 1.5 m distance four sides.
PARAMETER
MIN.
TYP.
MAX.
UNIT
COMMENT
Noise
-
32
34
dB A
In RGB mode