EasyManua.ls Logo

norxe P1 - 13 Environmental Conditions; Operating; Non-Operating; Storage & Transport

norxe P1
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© All Rights Reserved
www.norxe.com
P1 User Guide
Page 37 of 40
13 Environmental Conditions
Environmental conditions are common for both projector and projection lenses.
13.1 Operating
This test is performed with unit powered on and projecting an image.
PARAMETER
MIN.
TYP.
MAX.
UNIT
COMMENT
Temperature
0
20
40
Celsius
Fahrenheit
Humidity
20
80
% relative
humidity
Altitude
0
-
3,000
m
Shock
-
3
5
G
11ms,
3000 shocks
each axis
Random
vibration
-
-
0.5
G (RMS)
0.0052 G2/Hz,
30 min each
axis, 5-500 Hz
Sine sweep
vibration
-
3
-
G
2 oct/min, 10-
10000 Hz
13.2 Non-Operating
This test is performed with unit powered off (no projected image).
PARAMETER
MIN.
TYP.
MAX.
UNIT
COMMENT
Random
vibration
-
-
1.5
G (RMS)
0.052 G2/Hz, 30
min each axis,
5-500 Hz
Sine sweep
vibration/dwell
-
-
0.5
G
Dwell 30 min/2-
hour sweep, 5-
500Hz
13.3 Storage & Transport
These tests are performed with packaged unit in original, new packaging.
PARAMETER
MIN.
TYP.
MAX.
UNIT
COMMENT
Random
vibration
-
-
1.5
G (RMS)
180 min each
axis, 5-500 Hz
Free fall drop
test
-
-
930
36.6
mm
inches
All sides, two
corners, two
edges
Temperature
0
-
40
Celsius
Fahrenheit
Extended
temperature
-20
-
60
Celsius
Fahrenheit
Maximum 12
hours
Humidity
10
90
% relative
humidity
Altitude
0
0
-
-
3,000
98,000
m
feet

Other manuals for norxe P1