EasyManua.ls Logo

NUM 1050 M - Temporary Customisation; Customisation Overrun

Default Icon
388 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 - 6 en-938821/2
7.3 Temporary Customisation
Message displayed at initialisation
ALL S/W OPTIONS VALID
THIS SYSTEM IS NOT IN WARRANTY
CONTINUE? (Y/N)
Comment
This message should never be displayed on the end user's equipment: it would indicate the system has not been
customised.
The system may possibly be used, but without any contractual warranty.
Actions
Acknowledge the message.
Y
The system is available
The system error indicator «PRSMX» is displayed in the status window (See 3.1.3).
Contact the machine manufacturer to customise the equipment.
7.4 Customisation Overrun
Message displayed at initialisation
TOO MANY AXES OR SPINDLES OR TOO FEW PLC AXES
CONTINUE (Y/N)?
Comment
The number of spindles or axes given by the machine parameters exceeds the maximum set during customisation or
disagrees with the expected number of PLC only axes.
Actions
Acknowledge the message.
Y
The system is available, but the machining modes are inhibited.
The system error indicator «PRSOV» is displayed in the status window (See 3.1.3).
Modify the parameters related to axes and spindles (See Parameter manual).
Reset the system to take the new value into account.