A - 16 en-938821/2
M19: Spindle index
Indexing
Syntax: N.. [G97 S..] [M40-M45] [M03/M04] C±.. M19
Cancellation: M03/M04/M05
M40-M45: Spindle speed ranges
Syntax: N.. [G97 S..] [M03/M04] M40-M45
Cancellation: Cancellation mutuelle
M48*: Enable overrides
Feed rateSpindle speed
0 - 120%50 - 100%
Syntax: N.. M48
Cancellation: M49
M49: Disable overrides
Feed rateSpindle speed
100%100%
Syntax: N.. M49
Cancellation: M48
M61: Release of current spindle from axis group
Syntax: N.. M61
Cancellation: M62 to M65
M64*, M65, M62, M63: Control of spindles 1 to 4
Syntax: N.. [G97 S..] M62/M63/M64/M65 [M40-M45] M03/M04
Cancellation: cancel one another
M66*, M67, M68, M69: Measurement of spindles 1 to 4
Syntax: N..M66/M67/M68/M69
Cancellation: cancel one another