8.5 B3240 DPUs Specifications
OPNs
900-9D3B6-00CN-AB0: Crypto Enabled with integrated BMC
900-9D3B6-00SN-AB0: Crypto Disabled with integrated BMC
BlueField-3 IC
BlueField-3 P-Series - 16 Arm-Cores - 560MHz/2133MHz
Physical
Dual-Slot FHHL Card Dimensions: 111.15mm x 167.65mm
Tall Bracket Dimensions: 121.0mm x 21.6mm
Heatsink Dimensions (Length, Width, Height): 139.6mm x 92.7mm x 29.3mm
Interfaces
See Supported Interfaces
PCI Express Interface Gen 5.0 SERDES @ 32.0GT/s, 16 lanes (4.0, 3.0, 2.0
and 1.1 compatible)
Optional: Additional PCIe x16 Gen 4.0/5.0 @ SERDES
32GT/s through the PCIe auxiliary passive card and
Cabline SA-II Plus harnesses
On-board Memory Dual-channel with 20 DDR5 + ECC (128bit + 16bit
ECC) for a total of 32GB@ 5600MT/s
40GB pSLC eMMC memory + 128GB SSD
Networking Connector Dual QSFP112 (copper and optical)
Data Rate
InfiniBand(Default
Speed)
NDR/NDR200/HDR/HDR100/EDR/FDR/SDR
Ethernet 400/200/100/50/25/10 Gb/s
Protocol Support
InfiniBand: IBTA v1.5
(a)
Auto-Negotiation: NDR (4 lanes x 100Gb/s per lane) port, NDR200 (2 lanes x
100Gb/s per lane) port, HDR (50Gb/s per lane) port, HDR100 (2 lane x 50Gb/s
per lane), EDR (25Gb/s per lane) port, FDR (14.0625Gb/s per lane), 1X/2X/4X
SDR (2.5Gb/s per lane)
Ethernet:400GAUI-4 C2M, 400GBASE-CR4, 200GAUI-2 C2M, 200GAUI-4 C2M,
200GBASE-CR4, 100GAUI-2 C2M, 100GAUI-1 C2M, 100GBASE-CR4, 100GBASE-CR2,
100GBASE-CR1, 50GAUI-2 C2M, 50GAUI-1 C2M, 50GBASE-CR, 50GBASE-R2 ,
40GBASE-CR4, 40GBASE-R2, 25GBASE-R, 10GBASE-R, 10GBASE-CX4, 1000BASE-
CX, CAUI-4 C2M, 25GAUI C2M, XLAUI C2M , XLPPI, SFI
PCI Express 5.0: SERDES @ 32.0GT/s, 16 lanes (4.0, 3.0, 2.0 and 1.1 compatible)
Electrical and Thermal
Specifications
Voltage: 12V
Electrical and thermal specifications are provided in "NVIDIA BlueField-3 DPUs
and SuperNICs Electrical and Thermal Specifications" document. You can access
the document either by logging into NVOnline or by contacting your NVIDIA
representative.
Environmental
Temperature Operational 0°C to 55°C
Non-operational
-40°C to 70°C
(b)
Humidity Operational 10% to 85% relative
humidity
Non-operational 10% to 90% relative
humidity
Altitude (Operational) 3050m
Regulatory
Safety CB / cTUVus / CE