CAP.4 INSTALLAZIONE
QUESTEOPERAZIONISONODICOMPETENZA
ESCLUSIVADEITECNICISPECIALIZZATIINCARI
-
CATIDALCOSTRUTTOREODAIRIVENDITORI
AUTORIZZATI.
SEEFFETTUATEDAALTREPERSONEPOSSO
-
NOCREARESITUAZIONIDIPERICOLOECAU
-
SAREGRAVIDANNIALLEPERSONEE/OAL
SOLLEVATORE.
VERIFICADEIREQUISITIPERL’INSTALLAZIONE
Ilsollevatoreècostruitoperl’impiegoinlocalichiusieriparati.Il
luogopresceltonondeveesserevicinoalavaggi,apostidiverni
-
ciatura,adepositidisolventiovernici,alocaliconlavorazioniche
possonocreareatmosfereesplosive.
VERIFICADIIDONEITÀDELLEDIMENSIONIDELLOCALEE
DELLEDISTANZEDISICUREZZA.
Ilsollevatoredeveessereinstallatorispettandoledistanzedisicu
-
rezzadamuri,colonne,altremacchine,ecc...comeindicatein
Fig.31esecondoleeventualiprescrizionidellalegislazionevigen
-
tenelluogodiinstallazione.
Verificareinparticolare:
·
altezza:minimo5000mm(considerarel’altezzadeiveicolida
sollevaretenendocontochel’altezzamax.deibraccièdicirca
2000mm.).
·
distanzadaimuri:minimo700mm,
·
spaziperlavorare:minimo800mm,oltreledimensionidelvei
-
colodasollevare.
·
spaziperlaPOSTAZIONEDICOMANDO,
·
spaziperlamanutenzione,peraccessieviedifugaincasodi
emergenze.
· posizionerelativaallealtremacchine,
· possibilitàdirealizzarel’allacciamentoelettrico.
Nelcasodiofficineconpiù
sollevatori,lalorodisposizionedovrà
esseredefinitaedettagliatainbase
allenormedilavoroedisicurezza.
Fig.31 Distanzedisicurezza
ILLUMINAZIONE
Tuttelezonedellamacchinadevonoessereilluminateinmodo
uniformeesufficientepergarantireleoperazionidiregolazionee
manutenzioneprevistenelmanuale,evitandozoned’ombra,rifles
-
si,abbagliamentoeaffaticamentodellavista.
L’illuminazionedeveessererealizzatainaccordoconlanormativa
vigentenelluogodiinstallazione(acuradell’installatoredell’im
-
piantodiilluminazione).
CHAPTER4 INSTALLATION
THEFOLLOWINGOPERATIONSMUSTBEPER
-
FORMEDEXCLUSIVELYBYSPECIALISEDTECH
-
NICALSTAFFWITHAUTHORISATIONFROMTHE
MANUFACTURERORLICENSEDDEALER.
IFTHESEOPERATIONSAREPERFORMEDBY
OTHERPERSONS,SERIOUSPERSONALINJURY
AND/ORIRREPERABLEDAMAGETOTHELIFT
UNITMAYRESULT.
INSTALLATIONREQUISITECHECKLIST
Theliftisdesignedforinstallationinenclosedareassuitablypro
-
tectedfromtheweather.Theplaceofinstallationmustbewell
clearofareasdestinedtowashingorpainting,andawayfromsol
-
ventorpaintstorageareasorareaswherethereisariskofpoten
-
tiallyexplosiveatmosphere.
SUITABILITYOFTHEDIMENSIONSOFTHEPLACEOF
INSTALLATIONANDSAFETYCLEARANCES.
Theliftmustbeinstalledinobservanceoftheclearancesbetween
walls,pillars,othermachines,etc.indicatedinFigure31andin
compliancewithanylegislativerequirementsinthecountryofin
-
stallation.
Checkinparticular:
·
minimumheight:5000mminclusiveofheightofvehicleandma
-
ximumheightofarms,i.e.2000mm.
·
minimumdistancefromwalls:700mm,
·
minimumworkingarea:800mm,
·
areaforCOMMANDSTATION,
·
areaformaintenance,accessandemergencyescaperoutes.
·
positioninrelationtoothermachines,
·
proximitytopowersupplyfortrouble-freehook-up.
Ifinagarageseveralhoistsareinstal-
led,theiremplacementhastobecar-
riedoutaccordingtotherelevantla-
boursafetyrules.
Fig.31 Safetydistances
ILLUMINATION
Allpartsofthemachinemustbeuniformlylitwithsufficientlightto
assurethattheadjustmentandmaintenanceoperationsspecified
inthemanualcanbeperformed,andwithoutareasofshadow,re
-
flectedlight,glareandavoidingallsituationsthatcouldgiveriseto
eyefatigue.
Thelightingmustbeinstalledinaccordancewiththelawsinforce
intheplaceofinstallation(responsibilitylieswiththelighting
equip-mentfitter).
19