Bode 100
User Manual

Table of Contents

Other manuals for Omicron Lab Bode 100

Question and Answer IconNeed help?

Do you have a question about the Omicron Lab Bode 100 and is the answer not in the manual?

Omicron Lab Bode 100 Specifications

General IconGeneral
BrandOmicron Lab
ModelBode 100
CategoryMeasuring Instruments
LanguageEnglish

Summary

Safety instructions

Rules for use

Outlines essential guidelines and restrictions for the proper and safe use of the Bode 100.

Bode 100 and accessories

Technical data

Absolute maximum ratings

Lists the absolute maximum voltage and power ratings to prevent device damage.

Bode 100 specifications

Details the technical specifications of the Bode 100, including output, input, and interface characteristics.

Device overview

Bode Analyzer Suite introduction

Measurement configuration

Explains how to configure measurement parameters like frequency, source level, and attenuators.

Trace configuration

Details how to configure displayed traces, including measurement type, format, and axis settings.

Measurement types and applications

Gain measurement introduction

Introduces the two methods for measuring Gain: internal and external reference.

Impedance measurement introduction

Explains the basic equations and concepts related to measuring Impedance, Reflection, and Admittance.

Transmission / Reflection

Details the Transmission/Reflection measurement mode for S-parameter analysis in the 50 Ω domain.

Gain / Phase

Explains the Gain/Phase measurement mode for determining the transfer function using external reference.

One-Port

Details the One-Port measurement mode for quick impedance, admittance, and reflection measurements.

Impedance Adapter

Explains the Impedance Adapter mode for measurements using B-WIC and B-SMC test fixtures.

Shunt-Thru

Details the Shunt-Thru mode for measuring very small impedance values, based on S21 transmission.

Series-Thru

Explains the Series-Thru mode for measuring very high impedance values, based on S21 transmission.

Measurement and Device settings

Hardware setup

Describes the hardware setup dialog for configuring internal connections and external DUT connections.

Calibration / Correction

Internal device calibration

Explains the internal calibration process to compensate for device-internal signal path drift.

Performing a Gain Calibration

Guides users through the process of performing a Gain calibration (Thru calibration) for transmission measurements.

Calibrating a Transmission (S21) measurement

Details the setup and procedure for calibrating transmission (S21) measurements in the Transmission/Reflection mode.

Calibrating a Gain/Phase measurement

Explains the calibration setup for gain measurements in the Gain/Phase measurement mode.

Performing an Impedance Calibration

Explains the Open/Short/Load calibration procedure for compensating measurement setup parasitics.

Calibrating a Reflection or One-Port Impedance measurement

Details calibrating Impedance, Reflection, or Admittance in Transmission/Reflection or One-Port modes.

Calibrating an External Coupler or External Bridge measurement

Explains calibration for Impedance/Reflection/Admittance in External Coupler or Bridge modes.

Calibrating an Impedance Adapter measurement

Details calibration for Impedance Adapter mode using B-WIC and B-SMC fixtures.

Calibrating a Shunt-Thru or Series-Thru measurement

Covers calibration for Shunt-Thru and Series-Thru modes, enabling Thru or OSL calibration.

Calibrating a Voltage/Current measurement

Explains calibration for Voltage/Current mode, allowing Thru or OSL calibration.

Bode Analyzer Suite software features

Non-Invasive Stability Measurement

Details the Non-Invasive Stability Measurement (NISM) for determining phase margin.

Fres-Q Calculation

Explains the Fres-Q cursor calculation for contactless measurement of resonance frequency and quality factor.

Stability margin calculation

Covers automatic calculation of Phase Margin, Gain Margin, and Vector Stability Margin.

Automating measurements

Troubleshooting

Connection issues

Provides steps to diagnose and resolve issues related to connecting the Bode 100 and starting measurements.

Software problems

Offers guidance on troubleshooting software crashes or unexpected behavior and contacting support.

Related product manuals