CT Analyzer & CT SB2
User Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Omicron Lab CT SB2 and is the answer not in the manual?

Omicron Lab CT SB2 Specifications

General IconGeneral
BrandOmicron Lab
ModelCT SB2
CategoryMeasuring Instruments
LanguageEnglish

Summary

Preface

Operator Qualifications and Safety Standards

Details requirements for personnel operating the CT Analyzer and relevant safety standards.

Safety Rules

General Rules for Safe Operation

Outlines general safety rules for operating the CT Analyzer and its equipment.

1 Introduction

1.2 Functional Components of the CT Analyzer

Provides an overview of the CT Analyzer's operating elements and connectors.

2 Setup and Connection

2.1 General Safety Rules for Connecting and Operating the CT Analyzer

General safety guidelines for connecting and operating the CT Analyzer.

2.2 Setting Up the CT Analyzer

Step-by-step instructions for setting up the CT Analyzer.

2.4 Connection for Usual Applications

Details wiring for common CT testing applications like CT, Burden, and Resistance.

2.7 Improving the Quality of Measurement Results

Tips and techniques to enhance measurement accuracy and reduce errors.

4 Running a CT Test (Detailed)

4.2 Preparing and Configuring the Test

Steps to prepare and configure the CT test parameters.

4.3 Running the Automatic Test and Connecting the CT Analyzer

Guide to initiating the automatic test and managing connections.

5 Operating and Configuring the CT Analyzer

5.1 Working in the User Interface

Guidance on navigating and interacting with the CT Analyzer's user interface.

5.7 Settings

Accessing and configuring device settings and default test parameters.

6 The CT Analyzer Test Cards

6.2 CT-Object Card

Describes the main card for specifying CT data and test settings.

6.5 Resistance Card

Measures primary and secondary winding resistance of the CT.

6.6 Excitation Card

Traces the excitation curve and determines CT-specific parameters.

6.7 Ratio Card

Measures current ratio, error, and phase displacement.

6.8 Assessment Card

Shows automatic and manual assessment of tested parameters.

7 CT Testing Using the Guesser Function

7.1 About the Guesser Function

Explains the guesser function's purpose as an aid for unknown CT data.

7.3 Preparing and Configuring the Test

Steps to prepare and configure the CT test using the guesser function.

7.4 Running the Automatic Test

Guide to running the automatic test, considering guesser function configurations.

8 Using the Quick Test Feature

8.1 Safety Notes and Notes for Using Quick Test

Important safety warnings and notes specific to Quick Test usage.

8.3 Performing Measurements with Quick Test

Step-by-step guide to performing measurements using the Quick Test feature.

8.5 Polarity Check

Procedure for performing polarity checks using the CPOL polarity checker.

10 Technical Data

12 Error and Warning Messages

1 Introduction and Designated Use (CT SB2)

Multi-ratio CT testing

Enables automatic testing of multi-ratio CTs with up to 6 tap connections.

2 Hardware (CT SB2)

3 Measurement Setup (CT SB2)

3.3 Basic Measurement Setup for Multi-Ratio CT Testing

Basic wiring setup for multi-ratio CT testing using the CT SB2.

4 Short Guide for Multi-Ratio CT Testing Using the CT SB2

4.2 Configuring and Starting the Test

Configuring test parameters and initiating a multi-ratio CT test.

4.3 Automatic Test Execution

Details the automatic test execution sequence for multi-ratio CT tests.

5 Default Settings on the CT Analyzer for Multi-Ratio CT Testing

6 CT Analyzer Test Cards for Multi-Ratio CT Testing

6.1 CT-Object Card for Multi-Ratio CT Testing

Specifies CT data for multi-ratio testing in the CT-Object card.

6.2 MR-Config. Card

Configures the multi-ratio CT test, including taps and ratios.

6.3 MR-Results Card

Displays measurement results for each enabled tap or intertap combination.

9 Error and Warning Messages for the CT SB2