Parameter No. Data Description
Co
m
m
un
ica
tio
ns
fu
nc
tio
n
Reference item Page
3005Hex-02Hex to
3005Hex-06Hex,
3005Hex-63Hex,
3005Hex-64Hex
71 LSC-HLD:
Hold line speed control
frequency in the memory
E
Hold line speed con-
trol frequency in the
memory
page
7-79
72
CRUN-
M1:
Count the run time of
commercial power-driv-
en motor 1
O
Commercial switch
page
8-125
73
CRUN-
M2:
Count the run time of
commercial power-driv-
en motor 2
O
76 DROOP: Select droop control E Droop Control
page
8-134
78 MPRM1:
Select speed control pa-
rameter 1
E
Speed Control Set-
tings
page
7-26
79 MPRM2:
Select speed control pa-
rameter 2
E
80 Do not set. E - -
81 Do not set. E - -
82 AR-CCL:
Cancel anti-regenerative
control
E
Overvoltage Suppres-
sion Function during
Deceleration
page
8-74
84 LAC:
Acceleration and decel-
eration time cancel
E
Acceleration/decelera-
tion time setting
page
8-132
85 AHD: Analog command held O
Retention of analog
command function
page
8-39
94 FJOG:
Run forward with Jog-
ging
E
Jogging (JG)
page
6-53
95 RJOG:
Run reverse with Jog-
ging
E
97 F/R: 3-wire forward/reverse O 3-wire input function
page
6-50
98 FW:
Forward Run/Stop
*1
E
RUN command selec-
tion
Forward RUN Com-
mand (FW) and Re-
verse RUN Command
(RV)
page
6-22
page
6-49
99
RV:
Reverse Run/Stop
*2
E
119 P-SEL:
Proportional operation of
speed regulator
O Position control
page
7-36
8 Other Functions
8-26
M1 Series EtherCAT Type User’s Manual (I670)

Table of Contents