Index
(hex)
Subin-
dex
(hex)
Object name Setting range Unit Default setting Size Access
PDO
map
05 Flags 0000 to 003F hex --- 0000 hex 2 bytes
(U16)
RW Not pos-
sible
06 to
0D
Diagnosis Message
1-8
--- --- 00 hex 30 bytes
(OS)
RO Not pos-
sible
10F9 --- Present Time for Event Log
00 Number of Entries --- --- 01 hex 1 byte
(U8)
RO Not pos-
sible
01 Present Time for
Event Log
00 to
FFFFFFFFFFFFF
FFF hex
--- 00 hex 8 bytes
(U64)
RW Not pos-
sible
1600 --- 1st Receive PDO Mapping
00 Number of Objects in
this PDO
00 to 0A hex --- 00 hex 1 byte
(U8)
RW Not pos-
sible
01 to
0A
1st-10th Output Ob-
ject to be mapped
00000000 to
FFFFFFFF hex
--- 00000000 hex 4 bytes
(U32)
RW Not pos-
sible
1700 --- 257th Receive PDO Mapping
00 Number of Objects in
this PDO
--- --- 02 hex 1 byte
(U8)
RO Not pos-
sible
01 1st Output Object to
be mapped
--- --- 60400010 hex 4 bytes
(U32)
RO Not pos-
sible
02 2nd Output Object to
be mapped
--- --- 60420010 hex 4 bytes
(U32)
RO Not pos-
sible
1701 --- 258th Receive PDO Mapping
00 Number of Objects in
this PDO
--- --- 02 hex 1 byte
(U8)
RO Not pos-
sible
01 1st Output Object to
be mapped
--- --- 50000010 hex 4 bytes
(U32)
RO Not pos-
sible
02 2nd Output Object to
be mapped
--- --- 50100010 hex 4 bytes
(U32)
RO Not pos-
sible
1710 --- 273th Receive PDO Mapping
00 Number of Objects in
this PDO
--- --- 13 hex 1 byte
(U8)
RO Not pos-
sible
01 1st Output Object to
be mapped
--- --- E7000108 hex 4 bytes
(U32)
RO Not pos-
sible
02 2nd Output Object to
be mapped
--- --- 66400001 hex 4 bytes
(U32)
RO Not pos-
sible
03 to
08
3rd–8th Output Ob-
ject to be mapped
--- --- 00000001 hex 4 bytes
(U32)
RO Not pos-
sible
09 9th Output Object to
be mapped
--- --- 66320001 hex 4 bytes
(U32)
RO Not pos-
sible
0A to
1
1
10th-17th Output
Object to be mapped
--- --- 00000001 hex
4 bytes
(U32)
RO Not pos-
sible
12 18th Output Object
to be mapped
--- --- E7000310 hex 4 bytes
(U32)
RO Not pos-
sible
13 19th Output Object
to be mapped
--- --- E7000210 hex 4 bytes
(U32)
RO Not pos-
sible
1A00 --- 1st Transmit PDO Mapping
00 Number of Objects in
this PDO
00 to 10 hex --- 00 hex 1 byte
(U8)
RW Not pos-
sible
01 to
0A
1st-10th Input Object
to be mapped
00000000 to
FFFFFFFF hex
--- 00000000 hex 4 bytes