11 M16 Latest Alarm
Contents
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: No alarm
1: OC1 Overcurrent protection (dur-
ing acceleration)
2: OC2 Overcurrent protection (dur-
ing deceleration)
3: OC3 Overcurrent protection (dur-
ing constant speed operation)
6: OU1 Overvoltage protection (dur-
ing acceleration)
7: OU2 Overvoltage protection (dur-
ing deceleration)
8: OU3 Overvoltage protection (dur-
ing constant speed operation or stop-
ping)
10: LU Undervoltage protection
11: Lin Input phase loss protection
16: PbF Inrush Current Prevention
Circuit Error
17: OH1 Heat sink overheat
18: OH2 External alarm input
19: OH3 Inverter internal overheat
20: OH4 Motor protection (PTC ther-
mistor)
22: dbH Braking resistor overheat
23: OL1 Motor 1 overload
24: OL2 Motor 2 overload
25: OLU Inverter overload
27: OS Over speed protection
28: Pg PG disconnection
31: Er1 Memory error
32: Reserved
33: Er3 CPU error
34: Reserved
35: Er5 EtherCAT board error
36: Er6 Operation protection
37: Er7 Tuning error
0 --- --- Possible
(TxPDO)
12 M17 Last Alarm Con-
tents
13 M18 Second Last
Alarm Contents
14 M19 Third Last Alarm
Contents