Index
(hex)
Sub-
index
(hex)
Pa-
rame-
ter No.
Function name Monitor or data range
Default
data
Set-
ting
dur-
ing
RUN
Unit
PDO
map
10 E115 External DC In-
jection Braking
Edge/Level Se-
lection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Edge operation
1: Level operation
1 --- --- Possible
12 E117 2nd Frequency
Upper Limit
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00 to 590.00
70.00 --- Hz Possible
13 E118 2nd Frequency
Lower Limit
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00 to 590.00
0.00 --- Hz Possible
14 E119 PID Control
Feedback Selec-
tion
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Analog input
3: Pulse train input
0 --- --- Possible
15 E120 PID Control PID
Output V
ariable
Range for Proc-
ess Control
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0: Disable
0.1 to 100.0
0.0 --- % Possible
16 E121 PID Control PID
Feedforward Se-
lection for Proc-
ess Control
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Disable
1: Input terminal [AI1]
0 --- --- Possible
17 E122 1st AVR Function
Selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Disable
1: Enable
1 --- --- Possible
18 E123 2nd AVR Func-
tion Selection
19 E124 Energy-saving
Operation Func-
tion Selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Normal operation
1: Auto energy saving operation
0 --- --- Possible
1A E125 1st 2-step Accel-
eration/ Deceler-
ation switching
Condition Selec-
tion
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Switching by 2CH terminal
1: Switching by 2-step Acceleration
Switching Frequency/2-step Deceler-
ation Switching Frequency
2: Switching between forward/
reverse rotation only
3: Switching by RT1/R
T2 terminal
0 --- --- Possible
1B E126 2nd 2-step Accel-
eration/Decelera-
tion Switching
Condition Selec-
tion
Appendices
A-120
M1 Series EtherCAT Type User’s Manual (I670)