Index
(hex)
Sub-
index
(hex)
Pa-
rame-
ter No.
Function name Monitor or data range
Default
data
Set-
ting
dur-
ing
RUN
Unit
PDO
map
1F A30 2nd Magnetic
Saturation Factor
1
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 300.0
92
% Possible
20 A31 2nd Magnetic
Saturation Factor
2
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 300.0
84.2
% Possible
21 A32 2nd Magnetic
Saturation Factor
3
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 300.0
70.5
% Possible
22 A33 2nd Magnetic
Saturation Factor
4
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 300.0
58.3
% Possible
23 A34 2nd Magnetic
Saturation Factor
5
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 300.0
46.1
% Possible
29 A40 2nd Slip Com-
pensation Oper-
ating Conditions
Selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Enable during acceleration/decel-
eration, enable at base frequency or
higher
1: Disable during acceleration/decel-
eration, enable at base frequency or
higher
2: Enable during acceleration/decel-
eration, disable at base frequency or
higher
3: Disable during acceleration/decel-
eration, disable at base frequency or
higher
0 --- --- Possible
2A A41 2nd Output Cur-
rent Fluctuation
Damping Gain
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00 to 1.00
0.20
--- Possible
2C A43 Speed Control 2
Speed Command
Filter
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.000 to 5.000
0.02
s Possible
2D A44 Speed Control 2
Speed Detection
Filter
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.000 to 0.100
0.005
s Possible