Index
(hex)
Sub-
index
(hex)
Pa-
rame-
ter No.
Function name Monitor or data range
Default
data
Set-
ting
dur-
ing
RUN
Unit
PDO
map
45 J68 Brake Control
Brake-release
Current
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00 to 300.00
100.00
% Possible
46 J69 Brake Control
Brake-release
Frequency
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 25.0
1.0
Hz Possible
47 J70 Brake Control
Brake-release
Timer
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.000 to 5.000
1.000
s Possible
48 J71 Brake Control
Brake-applied
Frequency
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 25.0
1.0
Hz Possible
49 J72 Brake Control
Brake-applied
Timer
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.000 to 5.000
1.000
s Possible
5B J90 Overload Stop
Function P gain
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.000 to 2.000
999: 0.050
*1
999
--- Possible
5C J91 Overload Stop
Function Integral
time
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.001 to 9.999
999: 0.025
*1
999
s Possible
5D J92 Overload Stop
Function Current
level
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
50.0 to 150.0
100
% Possible
60 J95 Brake control
Brake-release
Torque
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00 to 300.00
100
% Possible
Appendices