EasyManua.ls Logo

Omron 3G3M1-A4004-ECT - Page 709

Omron 3G3M1-A4004-ECT
850 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Index
(hex)
Sub-
index
(hex)
Pa-
rame-
ter No.
Function name Monitor or data range
Default
data
Set-
ting
dur-
ing
RUN
Unit
PDO
map
2A d41 Special Control
Selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Disable (Normal control)
1: Enable (Peripheral speed constant
control)
0 --- --- Possible
34 d51 Reserved Do not use. --- --- --- ---
35 d52 Reserved Do not use. --- --- --- ---
38 d55 Reserved Do not use. --- --- --- ---
44 d67 Motor Starting
Mode Auto
Search in Speed
Sensor V
ector
Control
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Disable
1: Enable (Only at restart after mo-
mentary power failure)
2: Enable (At normal start and restart
after momentary power failure)
1 --- --- Possible
45 d68 Reserved Do not use. --- --- --- ---
47 d70 Speed Control
Slip Frequency
Limit
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00 to 100.00
100
% Possible
50 d79 Reserved Do not use. --- --- --- ---
51 d80 1st PM Motor
Magnetic Pole
Position Pull-in
Frequency
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.1 to 10.0
1
Hz Possible
52 d81 Reserved Do not use. --- --- --- ---
53 d82 Magnetic Flux
W
eakening Con-
trol Function Se-
lection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Disable
1: Enable
1
--- Possible
54 d83 Magnetic Flux
Weakening Low-
er Limit
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
10 to 70
40
% Possible
55 d84 Reserved Do not use. --- --- --- ---
56 d85 Reserved Do not use. --- --- --- ---
57 d86 Acc/Dec Output
Frequency Filter
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.000 to 5.000
0
s Possible
59 d88 Reserved Do not use. --- --- --- ---
Appendices
A-163
M1 Series EtherCAT Type User’s Manual (I670)
A-4 Lists of Manufacturer Specific Objects 2
(Inverter Parameters)
A
A-4-14 d Group Parameter List (Applied Functions 2)

Table of Contents

Related product manuals