216
Response
If the correct command code or parameter is set to the output word, the same
command code or parameter will be set to the input word.
If the wrong command code or parameter is set to the output word, one of the
following error codes will be set to the input word.
E000: This error code will be set to the input word if a nonexisting command code
is used.
E001: This error code will be set to the input word if the parameter is not within
the range covered by the Unit.
7-3-12 Hysteresis Read
This command is used to read the hysteresis.
Command
Command Code
Parameter Parameters are not used with this command.
Response
If the correct command code or parameter is set to the output word, the same
command code or parameter will be set to the input word.
Range: 0001 to 0999
Default value: 0001
If the wrong command code or parameter is set to the output word, one of the
following error codes will be set to the input word.
E000: This error code will be set to the input word if a nonexisting command code
is used.
7-3-13 Present Value Read
This command can be used only when the timing hold in operation mode A is set
to normal.
This command is used to read the present measured value after scaling.
Command
Command Code
Parameter Parameters are not used with this command.
Response
If the correct command code or parameter is set to the output word, the present
conversion data will be set to the input word.
Sign
0: Positive
F: Negative
Value
Range: 0 to 9999
Commands and Responses
Section 7-3